TENMAX : COMPOSITE TECHNICAL SOLUTIONS
TENMAX : COMPOSITE TECHNICAL SOLUTIONS
 
TENMAX can supply food grade composite materials approved by the FDA.

TENMAX composite materials are approved by the (American Petroleum institute) according to the API 610 10th edition:


Material Temperatur Limits Limiting Pressure
Diferential
Application
  Min Max    
PEEK TMC 30
Chopped carbon fibre filled
-30°C (-20°F) 135°C (275°F) 200 kPa (20 bar) (300 psi) Stationery Parts
TMCW70
Continuous carbon
fiber wound
-30°C (-20°F) 230°C (450°F) 3500 kPa (35 bar) (500 psi) or
14000 kPa (140 bar) (2000 psi)
if suitably supported
Stationery or rotating
Polyamide
Need Information
relative to experience.
Carbon graphite
Resin impregnated
Babbit impregnated
Nickel impregnated
Copper impregnated
-50°C (-55°F)
-100°C (-150°F)
-195°C (-320°F)
-100°C (-450°F)
285°C (550°F)
150°C (300°F)
400°C (750°F)
2000 kPa (20 bar) (300 psi)
2750 kPa (27.5 bar) (400 psi)
3500 kPa (35 bar) (500 psi)
Stationery parts


Non-metallic wear part materials, which are proven to be compatible with the specified process fluid, may be proposed within the above limits. See 5.7.4.c

Such materials may be selected as wear components to be mated against a suitably selected metallic component such as hardened 12% Cr steel or hardfaced austenitic stainless steel. Materials may be used beyond these limits if proven application experience can be provided, and if approved by the purchaser.